KX-DJFP2V compensation cable
  • KX-DJFP2V compensation cable

KX-DJFP2V compensation cable

Generally, PVC insulated and sheathed compensating wires or cables have excellent moisture-proof, wear-resistant, and flame retardant properties; High temperature resistant fluoroplastic insulated and sheathed compensation conductor or cable adopts continuous extrusion process, which has more advantages of high temperature resistance, cold resistance, acid, alkali, oil and water resistance, non flame retardancy, aging resistance, etc.

1: Product features and uses

Generally, PVC insulated and sheathed compensating wires or cables have excellent moisture-proof, wear-resistant, and flame retardant properties; High temperature resistant fluoroplastic insulated and sheathed compensation conductor or cable adopts continuous extrusion process, which has more advantages of high temperature resistance, cold resistance, acid, alkali, oil and water resistance, non flame retardancy, aging resistance, etc. The product quality is higher than the provisions of the national standard GB/T4989-94 (equivalent to IEC584-3).

The compensating wires or cables used in the intrinsically safe explosion-proof temperature measurement system are made of low capacitance and low inductance materials, which have explosion-proof safety performance. They are suitable for connecting explosion-proof thermocouples with explosion-proof temperature measurement instruments in environments with explosion hazards, forming an intrinsically safe thermocouple temperature measurement system.

2: Product execution standards

GB/T4989-94 (equivalent to IEC584-3 standard)

3: Usage characteristics

1. Conductor * * * High working temperature: Heat resistance level: Polyfluoroethylene propylene (F46) 200 ℃

Soluble polytetrafluoroethylene 260 ℃

Silicone rubber 180 ℃

Ordinary grade: PVC at 70 ℃ and 105 ℃, cross-linked polyethylene at 90 ℃

Low smoke halogen-free flame retardant polyolefin at 70 ℃, cross-linked at 90 ℃ and 125 ℃

2. Low ambient temperature: PVC sheath: fixed laying -40 ℃, non fixed laying -15 ℃

Fluoroplastic insulation and sheath: fixed laying -60 ℃, non fixed laying -20 ℃

3. Cable allowable bending radius: For non armored cables, the minimum allowable bending radius is 6 times the outer diameter

Copper tape shielded or steel tape armored point cable * * * is less than 12 times the outer diameter of the cable

Fluoroplastic insulation and sheath * * * are less than 10 times the outer diameter of the cable