Metal tube rotary flowmeter
  • Metal tube rotary flowmeter

Metal tube rotary flowmeter

The LZ series metal tube rotary flowmeter is a variable area flow instrument based on float position measurement. Adopting an all metal structure and Modular concept design, due to its small volume, low pressure loss, large range ratio (10:1), and convenient installation and maintenance, it is widely used in various industries for complex and harsh environments, flow measurement and process control under low flow rate, low flow rate, and various harsh media conditions.

1、 Product Overview:

The LZ series metal tube rotary flowmeter is a variable area flow instrument based on float position measurement. Adopting an all metal structure and Modular concept design, due to its small volume, low pressure loss, large range ratio (10:1), and convenient installation and maintenance, it is widely used in various industries for complex and harsh environments, flow measurement and process control under low flow rate, low flow rate, and various harsh media conditions.

The series of products for metal tube flow meters have multiple measurement forms for users to choose from according to different user needs and occasions; According to the output form, there are on-site indication type, remote output type, and control alarm type; According to explosion-proof requirements, it can be classified into three types: ordinary type, intrinsic safety type, and isolated explosion-proof type.

This intelligent signal transmitter adopts a non-contact magnetic measurement sensor to detect changes in magnetic field angle, and is equipped with a Motorola microprocessor system. It can achieve functions such as LCD indication, accumulation, remote output (4-20mA), pulse output, upper and lower limit alarm output, etc. It has high precision and reliability, can completely replace imported instruments of the same type, and has characteristics such as high cost-effectiveness, multi parameter calibration, and power-off protection.

The design and production of metal tube flow meters also consider the user's process flow requirements, and there are various installation methods available, including vertical installation, upper inlet and lower outlet installation, side inlet and side outlet installation, bottom inlet and side outlet installation, threaded connection, and horizontal installation.

2、 Working principle:

The LZ series metal tube rotary flowmeter is a force formed by the differential pressure between the upper and lower ends of the float when the measured medium passes through a conical measuring tube from bottom to top. When the lift force on the float is greater than the weight of the float immersed in the fluid, the float rises and the annular gap area increases. The fluid flow velocity at the annular gap immediately decreases, and the differential pressure between the upper and lower ends of the float decreases. The lifting force acting on the float also decreases until the lift force is equal to the weight of the float immersed in the fluid, and the float stabilizes at a certain height. The position of the float corresponds to the flow rate of the measured medium. The float is equipped with a built-in magnetic steel, and as the float moves up and down with the medium, the magnetic field changes with the float's movement.

a、 For the on-site type, the rotating magnetic steel in the on-site indicator couples with the magnetic steel inside the float, causing rotation and driving the pointer to indicate the current flow rate through the dial.

b、 For the intelligent type, a solid-state magnetic sensor in the intelligent indicator converts the change in magnetic field into an electrical signal, which is then converted into an A/D converter, microprocessor, D/A output, and displayed on an LCD to display the magnitude and cumulative flow rate.

3、 Flowmeter type:

According to the direction of the fluid inlet and outlet, the product is divided into five types: vertical type, horizontal type (also known as horizontal T-type, horizontal spring type), bottom in side out type, side in side out type, and side in top out type. Each type has standard type, high-temperature type, jacket type, etc.

When the diameter of the horizontally installed flowmeter is less than DN50 (inclusive), a T-shaped structure is selected, and when it is greater than DN50, a spring structure is selected.

Flowmeter connection specifications: The LZ series metal tube flowmeter standard model adopts the GB/T9119-2000 flange standard, and the flange standard can be made according to customer needs; Screw connection and clamp connection can also be selected.

Magnetic filter:

If the medium contains ferromagnetic particles, a magnetic filter should be installed before the inlet of the flow meter.

4、 Application scenarios:

The LZ series metal tube rotary flowmeter is a commonly used variable area flow measurement instrument in industrial automation process control. It has the characteristics of small volume, large detection range, and convenient use. It can be used to measure the flow rates of liquids, gases, and vapors, especially suitable for measuring medium flow rates with low flow rates and small flow rates. Widely used in complex and harsh environmental conditions such as petroleum, chemical, power generation, pharmaceuticals, food, water treatment, and various medium conditions for flow measurement processes.

5、 Main features:

1. All metal structure design, sturdy, simple, high-pressure resistant, high-temperature resistant, anti-corrosion, and long service life;

2. Short stroke, total height of 250mm, convenient installation;

3. Mechanical pointers indicate instantaneous flow rate on site, and LCD displays instantaneous flow rate and cumulative flow rate;

4. Intelligent indicator, using foreign signal acquisition and processing chips, modular design, without hysteresis;

5. Equipped with data recovery, data backup, power failure protection, and error self diagnosis functions;

6. Hart type indicator, two wire 24VDC power supply, 4-20mA standard current signal output superimposed with the Hart protocol;

7. Parameter configuration and on-site adjustment can be carried out through a Hart communication manual operator;

8. Connect to the PC serial port and calibrate the instrument on site through a Windows program;

9. Can be used in flammable and explosive hazardous environments;

10. There are various installation forms such as vertical, horizontal, top in and bottom out, bottom in and side out, and side in and side out, with flange or threaded connections.

6、 Technical parameters:

1. Measurement range: Water 2.5~100000l/h (20 ℃);

2. Range ratio: 10:1;

3. Accuracy levels: 1.0, 1.5, 2.5

4. Working pressure: PN4.0 MPa for DN15, DN25, and DN50, with a maximum of 10.0MPa; PN1.6 MPa for DN80 and DN100, with a maximum of 6.4MPa;

5. Medium temperature: -40 ℃~300 ℃;

6. Medium viscosity: DN15: η<5mPa · s (F15.1~F15.3); η<30mPa · s (F15.4~F15.8);

DN25:η<250mPa·s

DN50~DN150:η<300mPa·s;

7. Environmental temperature: LCD type: -40 ℃~85 ℃; Pointer type: -40 ℃~120 ℃;

8. Connection form: flange (according to standard DIN2501 or manufactured according to the flange standard provided by the user)

9. Instrument height: 250mm

10. Cable interface: M20 * 1.5

11. Power supply: 24VDC two wire system 4-20mA or 85-265VAC 50/60Hz (remote transmission type)

12. Alarm output: Upper or lower limit instantaneous flow alarm relay output (contact capacity greater than 5A-250VAC) or open collector output (internal impedance greater than 100mA-30VDC, 100 Ω).

13. Pulse output: Accumulated pulse output, with small intervals of one pulse every 10 seconds (AC type) or one pulse every 50 milliseconds.

14. LCD display: Double row LCD display, displaying instantaneous flow rate and cumulative flow rate

15. Intrinsic safety explosion-proof: Exia II CT4.

16. Measurement tube material: 316 stainless steel (ordinary type) or lined with polytetrafluoroethylene (anti-corrosion type).

皖ICP备15014265号-8