The stainless steel electric contact bimetallic thermometer dial is made of stainless steel material and is mainly used in production sites with corrosive environments or media containing food grade substances, where automatic temperature control and alarm control output are required. Stainless steel electric contact bimetallic thermometer can directly measure the temperature of liquid, steam, and gas media within the range of -80 to 500 ℃ in various production processes.
1、 Characteristics
·The shell material is made of stainless steel, which can withstand environmental corrosion
·On site temperature display, intuitive and convenient;
·Equipped with automatic power cut-off and alarm functions;
·Safe and reliable, with a long service life;
·Multiple structural forms can meet different requirements.
2、 Working principle
The stainless steel electrical contact bimetallic thermometer uses temperature changes to drive contact changes. When it is disconnected from the upper and lower limit contacts, it activates the relay in the circuit, thereby automatically controlling and alarming.
3、 Main technical parameters
·Product execution standard: JB/T8803-1998 GB3836-83
·Scale plate nominal diameter: 100
·Accuracy level: 1.5 (1.0)
·Thermal response time: ≤ 40S
·Protection level: IP55
·Normal working atmospheric conditions: temperature -25~+55 ℃, relative humidity ≤ 85%
·Set point error: The set point error should not exceed 1.5 times the basic error limit.
·Switching error: The switching error should not exceed 1.5 times the basic error limit.
·Switching repeatability: The switching repeatability limit range shall not exceed 1/2 of the basic error limit ****** value.