FVF-32 Power Cable
  • FVF-32 Power Cable

FVF-32 Power Cable

In addition to the above standards, flame retardant cables are classified into three different flame retardant categories: A, B, and C according to the GB/T18380.3-2001 standard. The flame retardant performance of Class A is excellent, and users can choose according to their needs.

1、 Product standards:

This product is produced according to GB/T 12706.1-2002 or IEC 60502 standards, and can also be produced according to other standards requested by users.

In addition to the above standards, flame retardant cables are classified into three different flame retardant categories: A, B, and C according to the GB/T18380.3-2001 standard. The flame retardant performance of Class A is excellent, and users can choose according to their needs.

The fire resistance performance of fire-resistant cables should comply with GB/119216.21-2003.

Halogen free low smoke flame-retardant cables are produced according to enterprise standards. The flame retardant performance is divided into different flame retardant categories A, B, and C according to the GB/T18380.3-2001 standard. The smoke concentration passes the test specified in GB/T17651-1998, and the pH value and conductivity should comply with the provisions of GB/T17650.2-1998.

2、 Product model:

VV, VLV - PVC insulated PVC sheathed power cables

VY, VLY - PVC insulated polyethylene sheathed power cables

VV22, VLV22- PVC insulated steel tape armored PVC sheathed power cables

VV23, VLV23- PVC insulated steel tape armored polyethylene sheathed power cables

VV32, VLV32- PVC insulated fine steel wire armored PVC sheathed power cables

VV33, VLV33- PVC insulated fine steel wire armored polyethylene sheathed power cables

Flame retardant cable model: Add ZA, ZB, and ZC before the regular power cable model

Fire resistant cable model: Add N before ordinary power cable model

3、 Main features:

1. Uo/U is 450/750, 300/500, 300/300V

2. The long-term allowable temperature of the cable should exceed 105 ℃ for -105 model cables; The allowable working temperature for other models should not exceed.

3. The laying temperature of cables should not be lower than 0 ℃; Permissible bending radius: (B series), for cables with an outer diameter (D) less than 25mm, the allowable bending radius should not be less than 4D; For cables with an outer diameter (D) of 25mm or more, a bending radius of not less than 6D is allowed.

4. The flame retardant performance of flame-retardant cables (wires) should pass the combustion test of bundled wires and cables in GB/T 18380.3-2001.

5. The fire resistance performance of fire-resistant cables (wires) should pass the fire resistance test specified in GB/T 19216.21-2003.