1、 Executive standard: Q/TAT7689
2、 Usage: This cable is an intrinsic safety cable, also known as an intrinsic safety cable. It has low capacitance and low inductance, as well as shielding and anti-interference performance, thus its explosion-proof performance is better than that of general computer cables and control cables. It is suitable for use as a propagation line in circuits such as distributed systems and automated detection and control systems with explosion-proof requirements, and has super flexibility and high temperature resistance.
3、 Usage characteristics:
Rated voltage Uo/U: 300/500V
Maximum working temperature: generally not exceeding 70 ℃
The maximum temperature of the model with 105 after it does not exceed 105 ℃
Minimum ambient temperature: -40 ℃ for fixed installation, -15 ℃ for non fixed installation
Minimum bending radius: unarmored cables should not be less than 6 times the outer diameter of the cable
Armored cables should not be less than 12 times the outer diameter of the cable
4、 Main technical indicators:
Technical indicators of the project unit
Pe insulated PVC insulated
Working capacitance (core core) (1kHz) ≤ pF/M 90 180
Unbalanced capacitance (1kHz) ≤ pF/M 1/
Distributed inductance ≤ μ H/m 0.6 0.6
Inductance to resistance ratio ≤ 0.5mm2 μ H/Ω 20 20
0.75mm2
1.0mm2 25 25
1.5mm2 35 35
Resistance to external magnetic field interference (400A/m) ≤ mV 5 5
Anti static induction (20kV) ≤ mV 80 80
Anti RF interference (120dB) dB 60 60
Insulation resistance (20) ℃ M Ω. km 5000 25
Test voltage V/1min 1000 1000 1000
Flame retardancy meets the requirements of GB12666-90 and meets the requirements of GB12666-90